Analisa Sampel Komposite Dengan Menggunakan XRF Metode Fuse Bead Untuk Mengurangi Pemakaian Flux Pada Analisa Nikel Ore

Main Article Content

Irawati Ramli
Nurhikmah Wahab
Rizka Octavia
Alfiah Indriastuti
Riki Kusumah

Abstract

Composite analysis in a geological or mining context, especially for nickel ore, the theoretical basis refers to the concept of sampling and mineral processing. Composite sampling is carried out to obtain an accurate representation of a mineral deposit. Composite samples involve combining several individual samples to represent the overall properties of a material. The importance of composite data in processing mineral reserve information. Composite samples are used to smooth out fluctuations in mineral content and allow a better estimate of the average value of mineral content in the deposit. The implementation stage of this research consists of a small number of samples from several parts (a, c, d) being mixed into one combined sample, which is then analyzed to produce results that represent the average of all samples, by taking 0.25 grams of each sample to reach a total of 1 gram, then analyze the combined results. And using an X-Ray Fluorescence (XRF) tool with the Fuse Bead method. From the results of the research conducted by the author, a conclusion was obtained that it met the acceptance requirements. The accuracy rate obtained was 99.21%. which has a low error rate of 0.79%. The use of flux in the composite stage is more profitable, in terms of the efficiency of adding flux and the efficiency of working on samples compared to using the usual stage which still uses the process of processing samples one by one with the addition of more flux from the composite stage

Article Details

How to Cite
[1]
Irawati Ramli, Nurhikmah Wahab, Rizka Octavia, Alfiah Indriastuti, and Riki Kusumah, “Analisa Sampel Komposite Dengan Menggunakan XRF Metode Fuse Bead Untuk Mengurangi Pemakaian Flux Pada Analisa Nikel Ore”, djtech, vol. 5, no. 1, pp. 94-99, Jul. 2025.
Section
Dewantara Journal of Technology Volume 5 Nomor 1

References

Callister, William D, Jr. 2008. Materials Science and Engineering: An Introduction 8th Edition. New York: John Wiley & Sons, Inc.

Crundwell, F. K., Moats, M. S., Ramachandran, V., Robinson, T. G., & Davenport, W. G. (2011). Extractive Metallurgy of Nickel, Cobalt, and Platinum-Group Metals.

Dalvi, Ashok D, W Gordon Bacon, dan Robert C Osborne.(2004). The Past and The Future of Nickel Laterites. Canada : Inco Limited.

Gibson, R. F. 1984. Pinsiple of Composite Material Mechanics. New York: Mc Graw Hill.

Jamaludin, A.M. dan Tahir, D., (2016). Analisis Kandungan Logam Oksida Menggunakan Metode XRF (X-RayFlourescence).UniversitasHasanuddin.

K. van Rijswijk. 2001. Natural Fibre Composites Structures and Materials. Laboratory Faculty of Aerospace Engineering Delft University of Technology

Pickles, C.A., J. Forster., R. Elliott. (2014). Thermodynamic Analysis of The Carbothermic Reduction Toasting of A Nickeliferous Limonitic Laterite Ore. Minerals Engineering. Vol. 65, page. 33– 40.

Rosika K., Arif Nugroho. (2005) Aplikasi XRF (X-Ray Fluorescence) Untuk Analisa Unsur Dalam Bahan. Prosiding Pertemuan Ilmiah Nasional & Expo IPTEK MIPA. FMIPA-UI Depok: FMIPA-UI.

Riyanto. 2014. Validasi dan Verifikasi Metode Uji Sesuai dengan ISO/IEC 17025 Laborato-rium Pengujian dan Kalibrasi. Deepublish. Yogyakarta.

Siregar, C. J. P. 2007. Praktek Sistem Manajemen Laboratorium Pengujian yang Baik. EGC. Jakarta

Sukaryono,I.D., Hadinoto,S. Fasa,L.R. (2017). Verifikasi Metode Pengujian Cemaran Logam pada Air Minum Dalam Kemasan (AMDK) dengan Metode AAS-GFA, Majalah Biam-Kementerian Perindustrian. 8-16.

Schwartz, M.M. 1984. Composite Materials Handbook. NewYork: McGraw-Hill Inc.

SOCHACIM-XRF Scientific. 2010. X-Ray Fluorescence Sample Preparation Equipment and Accessories. European: SOCHACIM-XRF Scientific