Identifikasi Identifikasi Parameter Model First Order Plus Dead Time (FOPDT) untuk Analisis Dinamika Proses pada Reboiler 212-V14 Unit Hydrocracker Kilang Minyak
DOI:
https://doi.org/10.59563/djtech.v6i2.375Keywords:
FOPDT, Heavy Key, Hydrocracker, Light Key, Process DynamicAbstract
This study aims to analyze the effect of changes in TOP V14 temperature and light key (LK) flow rate on the dynamic behavior of a fractionation column process, as well as to develop a mathematical model for designing an Advanced Process Control (APC) algorithm. The research employed an experimental approach combined with system identification to determine the process response characteristics. The results show that increasing the TOP temperature from 112°C to 128°C raises the LK flow rate from 11 to 14 flow units, with a process gain (Kp) of 0.517 and a time constant (τ) of 4.989 minutes. At the same time, the heavy key (HK) flow rate also increases from 22 to 35 flow units, with a Kp value of 0.998 and a τ value of 3.777 minutes. Although the HK response reaches its final condition relatively quickly, the presence of dead time still causes a delay in the overall process response. These findings indicate that the implementation of APC for controlling LK and HK has strong potential to enhance process performance and provide significant economic benefits.
References
M. Imam, Statistik Indonesia 2024, vol. 52. Badan Pusat Statistik, 2024.
I. N. Istiqomah, A. Ma’rifatul Maghfiroh, and U. Bojonegoro, “Proses Pengolahan Minyak Mentah di Unit Kilang PPSDM MIGAS CEPU,” 2022.
C. Anditya and B. Prananto, Handbook of Energy and Economic Statistics of Indonesia 2024. 2024.
M. J. Willis, M. T. Tham, M. Willis, and M. Tham, “Advanced Process Control,” 1994.
I. F. U. Muzayanah, H. H. Lean, D. Hartono, K. D. Indraswari, and R. Partama, “Population density and energy consumption: A study in Indonesian provinces,” Heliyon, vol. 8, no. 9, Sep. 2022, doi: 10.1016/j.heliyon.2022.e10634.
S. T. Risdiyanta, “Mengenal Kilang Pengolahan Minyak Bumi (Refinery) Di Indonesia,” 2020.
L. Rahmayanti, D. M. Rahmah, and D. Larashati, “Analisis Pemanfaatan Sumber Daya Energi Minyak Dan Gas Bumi Di Indonesia,” Jurnal Sains Edukatika Indonesia (JSEI), vol. 3, no. 2, pp. 9–16, 2021.
C. Cox, J. Tindle, and K. Burn, “A comparison of software-based approaches to identifying FOPDT and SOPDT model parameters from process step response data,” Appl. Math. Model., vol. 40, no. 1, pp. 100–114, Jan. 2016, doi: 10.1016/j.apm.2015.05.007.
R. Aziz, “Perancangan Kendali Pid Dengan Model Process Reaction Curve Pada Showcase Jamur Merang.”
A. Penelitian, A. Y. Pratama, N. Gusrianti, and K. A. Haq, “Peran Mahasiswa Dalam Meningkatkan Literasi Digital,” Jurnal Tonggak Pendidikan Dasar, vol. 1, pp. 96–101, 2022, [Online]. Available: https://online-journal.unja.ac.id/jtpd/about
S. Madrigal, O. Arrieta, J. D. Rojas, M. Meneses, and R. Vilanova, “Fractional-Order PID Optimal Tuning Rule based on a FOPDT Process Model with Robustness Constraints,” in IFAC-PapersOnLine, Elsevier B.V., Jun. 2024, pp. 358–363. doi: 10.1016/j.ifacol.2024.08.088.
C. I. Muresan and C. M. Ionescu, “Generalization of the FOPDT model for identification and control purposes,” Processes, vol. 8, no. 6, Jun. 2020, doi: 10.3390/PR8060682.
M. K. Reitano, “Advanced Process Control Applications in Complex Industrial Processes,” 2021.
A. Mhamdi, K. I. Taarit, and M. Ksouri, “Identification of first-order plus dead time using typical test signals,” in Proceedings of 2016 4th International Conference on Control Engineering & Information Technology, 2016, pp. 16–18.
K. J. Åström and T. Hägglund, “Revisiting the Ziegler-Nichols step response method for PID control,” J. Process Control, vol. 14, no. 6, pp. 635–650, Sep. 2004, doi: 10.1016/j.jprocont.2004.01.002.
A. Madady and H. R. Reza-Alikhani, “Stabilization of control loops consisting of FOPDT process and parameter-dependent PID controller,” J. Process Control, vol. 22, no. 9, pp. 1688–1701, Oct. 2012, doi: 10.1016/j.jprocont.2012.07.001.
M. Frątczak, P. Nowak, P. Grelewicz, and J. Czeczot, “Concept of the advanced cloud-based autotuning procedure for PID controllers implemented in programmable logic controllers,” Advances in Science and Technology Research Journal, vol. 20, no. 4, pp. 413–426, 2026, doi: 10.12913/22998624/214684.
R. Bajarangbali, S. Majhi, and S. Pandey, “Identification of FOPDT and SOPDT process dynamics using closed loop test,” ISA Trans., vol. 53, no. 4, pp. 1223–1231, 2014, doi: 10.1016/j.isatra.2014.05.014.
T. Liu, Q. G. Wang, and H. P. Huang, “A tutorial review on process identification from step or relay feedback test,” 2013. doi: 10.1016/j.jprocont.2013.08.003.
M. Bauer and I. K. Craig, “Economic assessment of advanced process control - A survey and framework,” Jan. 2008. doi: 10.1016/j.jprocont.2007.05.007.
J. Chen, “System identification and control of FOPDT or SOPDT processes,” in Advanced Materials Research, 2011, pp. 2393–2397. doi: 10.4028/www.scientific.net/AMR.317-319.2393.